| UL STYLE |
VOLT RATING |
TEMP RATING |
INSULATION MATERIAL |
INSULATION THICKNESS |
JACKET THICKNESS |
CONDUCTOR OPTIONS |
USE |
| 2092 |
300V |
60 C |
PE/PVC |
.015"/.013" |
.015"/.013" |
30-16 AWG |
internal wiring of electronic equipment |
| 2093 |
300V |
60 C |
PE |
.015"/.013" |
.015"/.013" |
30-16 AWG |
internal wiring of electronic equipment |
| 2094 |
300V |
60 C |
PE/PVC |
.015"/.013" |
SEE SPEC |
30-16 AWG |
internal wiring of electronic equipment |
| 2095 |
300 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
32 AWG |
internal wiring of electronic equipment and appliances |
| 2096 |
300V |
80 C |
PVC |
.015"/.013" |
.015"/.013" |
2-8 30-16 AWG |
internal wiring of appliances and electronic equipment |
| 2097 |
300 V |
80 C |
PVC |
.015"/.013" |
.015"/.013" |
30-16 AWG |
for electronic use in non-hazardous locations |
| 2098 |
300 V |
90 C |
PVC |
1/64" |
1/64" |
26-16 AWG |
for electronic use in non-hazardous locations |
| 2099 |
300 V |
90 C |
PVC |
1/64" |
1/64" |
26-16 AWG |
for electronic use in non-hazardous locations |
| 2100 |
300 V |
90 C |
PVC |
.015"/.013" |
.015"/.012" |
36-16 AWG |
internal wiring |
| 2101 |
300 V |
105 C |
PVC |
.015"/.013" |
.015"/.013" |
30-16 AWG |
internal wiring of electronic equipment in non-hazardous locations |
| 2102 |
300 V |
105 C |
PVC |
.015"/.013" |
.015"/.013" |
30-16 AWG |
internal wiring of electronic equipment in non-hazardous locations |
| 2103 |
300 V |
105 C |
PVC |
.015"/.013" |
SEE SPEC |
30-10 AWG |
internal wiring of electronic equipment |
| 2127 |
600 V |
105 C |
PVC |
.030"/.027" |
.030"/.024" |
2 EA 28-9 AWG |
internal wiring of appliances and electronic equipment |
| 2129 |
1000 V |
105 C |
PVC |
.030"/.027" |
SEE SPEC |
28-9 AWG |
internal wiring of appliances and electronic equipment |
| 2265 |
300 V |
80 C |
PVC |
1/64" |
1/64" |
2-6,26-16 AWG, SOLID OR STRANDED, TINNED OR BARE COPPER |
internal wiring of appliances |
| 2343 |
N/S |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
30 AWG MIN STRANDED |
external interconnection of commuters and electronic equipment |
| 2344 |
N/S |
80 C |
PVC |
SEE SPEC |
.080"/.064" |
30 AWG MIN STRANDED |
external interconnection of computers and electronic equipment |
| 2345 |
N/S |
80 C |
PVC |
SEE SPEC |
.110"/.088" |
30 AWG MIN STRANDED COPPER |
external interconnection of computers and electronic equipment |
| 2346 |
N/S |
80 C |
PVC |
SEE SPEC |
.140"/.112" |
30 AWG MIN STRANDED COPPER |
external interconnection of computers and electronic equipment |
| 2384 |
30 V |
60 C |
PVC |
SEE SPEC |
.030"/.025" |
40 AWG MIN MATERIAL NOT SPECIFIED |
Construction A - internal wiring Construction B - internal or external wiring Construction C - external wiring for lighting fixtures |
| 2385 |
30 V |
60 C |
N/S |
SEE SPEC |
.060"/.048" |
40 AWG MIN |
internal wiring or external interconnection in class 2 circuits of electronic computers and electronic business machines |
| 2386 |
30 V |
60 C |
N/S |
SEE SPEC |
.080"/.064" |
40 AWG MIN MATERIAL NOT SPECIFIED |
internal wiring or external interconnection in class 2 circuits of electronic computers and electronic business machines |
| 2387 |
30 V |
60 C |
N/S |
SEE SPEC |
.110"/.088" |
40 AWG MIN |
internal wiring or external interconnection in class 2 circuits of electronic computers and electronic equipment |
| 2388 |
30 V |
60 C |
N/S |
SEE SPEC |
.140"/.112" |
40 AWG MIN |
internal wiring or external interconnection in class 2 circuits of electronic computers and electronic equipment |
| 2448 |
30 V |
80 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
internal wiring or external interconnection in class 2 circuits of electronic equipment |
| 2462 |
300 V |
60 C |
PVC |
SEE SPEC |
SEE SPEC |
SEE SPEC |
CONSTRUCTION A: internal wiring CONSTRUCTION B: internal wiring or external interconnection of electronic equipment; or internal wiring of appliances at temps not exceeding 60c |
| 2463 |
600 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
CONSTRUCTION A: internal wiring of x-ray equipment or in the internal or external interconnection of electronic equipment CONSTRUCTION B: external interconnection of electronic equipment in abuse area, such as x-ray equipment and business machine |
| 2464 |
300 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
SEE SPEC |
internal wiring of external interconnection of electronic equipment such as desk type calculators, dictating machines, or x-ray equipment |
| 2476 |
300 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
SEE SPEC |
Flat Ribbon Cable - internal wiring in electronic equipment |
| 2490 |
N/S |
60 C |
PVC |
SEE SPEC |
SEE SPEC |
36 AWG MIN |
external interconnection of computer and electronic equipment |
| 2493 |
N/S |
60 C |
PVC |
SEE SPEC |
SEE SPEC |
30-16 AWG |
external interconnection of electronic equipment |
| 2501 |
600 V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
internal wiring or external interconnection of electronic equipment at temp not exceeding 105c |
| 2502 |
30 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
internal wiring or external interconnection of electronic equipment |
| 2516 |
600 V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
external interconnection of electronic equipment |
| 2517 |
300 V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
external wiring of electronic equipment or internal wiring of electronic equipment or appliances |
| 2532 |
30 V |
80 C |
SEE SPEC |
SEE SPEC |
.030"/.024" |
40 AWG MIN MATERIAL NOT SPECIFIED |
external interconnection of electronic equipment |
| 2547 |
NS |
80 C |
PVC |
SEE SPEC |
.012"/.012 |
30-16 AWG |
internal wiring of electronic equipment where not exposed to movement or mechanical abuse |
| 2549 |
300 V |
90 C |
PVC |
SEE SPEC |
SEE SPEC |
40-16 AWG |
internal wiring or external interconnection of electronic equipment |
| 2550 |
600 V |
90 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
internal wiring or external interconnection of electronic equipment |
| 2552 |
30 V |
60 C |
PE or PP |
.005"/.100" |
SEE SPEC |
40 AWG MIN |
class 2 wiring of electronic equipment |
| 2560 |
30 V |
60 C |
PVC |
SEE SPEC |
SEE SPEC |
SEE SPEC |
internal connection for use with EDP equipment where terminated in connectors and located entirely exterior to the equipment, class 2 wiring systems only |
| 2570 |
600 V 1000V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
40-9 AWG |
external interconnection or internal wiring of electric equipment |
| 2571 |
N/S |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
internal wiring or external interconnection of electronic equipment |
| 2574 |
30 V |
105 C |
SEE SPEC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
external interconnecting cable for electric data, processing class 2 circuits where terminated in connectors and located entirely exterior to the equipment |
| 2576 |
150 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
36-9 AWG |
external interconnection or internal wiring of electric equipment |
| 2584 |
125 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
40-9 AWG |
external interconnection or internal wiring of electric equipment |
| 2586 |
600 V 1000V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
external interconnection or internal wiring of electric equipment |
| 2587 |
600 V |
90 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
external interconnection or internal wiring of electric equipment |
| 2589 |
30 V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
SEE SPEC |
external interconnection or internal wiring of electric equipment |
| 2598 |
300 V |
60 C |
PVC |
SEE SPEC |
SEE SPEC |
SEE SPEC |
external interconnection or internal wiring of electric equipment |
| 2614 |
30 V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
external interconnection or internal wiring of electric equipment |
| 2626 |
30 V |
80 C |
SEE SPEC |
SEE SPEC |
SEE SPEC |
N/S |
as internal wiring or external interconnection in class 2 circuits of computers and electronic equipment |
| 2630 |
125 V |
90 C |
PVC |
SEE SPEC |
SEE SPEC |
30-9 AWG |
external interconnection or internal wiring of electric equipment |
| 2631 |
N/S |
90 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN STRANDED |
external interconnection or computers and electronic equipment |
| 2637 |
30 V |
90 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
as internal wiring or external interconnection in class 2 circuits of computers and electronic equipment |
| 2653 |
600 V |
90 C |
PVC |
SEE SPEC |
SEE SPEC |
44-4/0 AWG |
external interconnection of electronic equipment |
| 2654 |
300 V |
90 C |
PVC |
SEE SPEC |
SEE SPEC |
36-6 AWG |
external interconnection of electronic equipment |
| 2655 |
300 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
36-6 AWG |
external interconnection of electronic equipment |
| 2656 |
600 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
36-6 AWG |
external interconnection of electronic equipment |
| 2660 |
N/S |
60 C |
N/S |
SEE SPEC |
SEE SPEC |
SEE SPEC |
internal and external interconnection of electronic equipment |
| 2661 |
300 V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
40-6 AWG |
external interconnection of electronic equipment |
| 2662 |
600 V |
105 C |
PVC |
SEE SPEC |
SEE SPEC |
33-10 AWG |
external interconnection of electronic equipment |
| 2668 |
30 V |
60 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
internal wiring or external interconnection of electronic equipment |
| 2679 |
60 V |
60 C |
N/S |
SEE SPEC |
SEE SPEC |
32 AWG MIN |
for use with electronic computers and business machines, class 2 wiring systems only |
| 2704 |
30 V |
60 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN, MATERIAL NOT SPECIFIED |
as internal wiring or external interconnection in class 2 circuits of computers and electric business machines |
| 2709 |
30 V |
60 C |
PVC |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
external interconnection or internal wiring of electronic equipment in class 2 wiring systems |
| 2725 |
30 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
.009"/.007" |
internal wiring of electronic equipment in class 2 systems only |
| 2726 |
30 V |
60 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN, MATERIAL NOT SPECIFIED |
internal wiring in electronic equipment |
| 2754 |
N/S |
80 C |
N/S |
SEE SPEC |
SEE SPEC |
N/S |
internal wiring or test probe leads for electronic testing and measuring equipment |
| 2787 |
150 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
30-16 AWG |
Irradiated PVC external interconnection of electronic equipment |
| 2789 |
30 V |
60 C |
PVC |
SEE SPEC |
SEE SPEC |
N/S |
as internal wiring or external interconnection in class 2 circuits of electronic equipment |
| 2919 |
30 V |
80 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
as internal wiring or external interconnection in class 2 circuits of computers and electric business machines |
| 2935 |
300 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
SEE SPEC |
internal wiring or external interconnection of electronic equipment |
| 2960 |
30 V |
60 C |
PP or PE |
.030"/.0035" |
SEE SPEC |
32 AWG MIN |
CONSTRUCTION A: internal wiring of electronic equipment (such as computers and electronic business machines) CONSTRUCTION B: external interconnection of electronic computers and electric business machines |
| 2990 |
30 V |
80 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
internal wiring or external interconnection of electronic equipment, class 2 circuits only |
| 3484 |
600 V |
125 C |
EP RUBBER |
SEE SPEC |
SEE SPEC |
30-4/0 AWG |
internal wiring of lighting fixtures, appliances or electronic equipment, where exposed to temp not exceeding 125 c |
| 20135 |
N/S |
60 C |
PVC |
SEE SPEC |
.030"/.024" |
40-16 AWG |
for external use in a medical cable assembly |
| 20233 |
300 V |
80 C |
PVC |
SEE SPEC |
SEE SPEC |
36 AWG MIN |
external interconnection of electronic equipment |
| 20234 |
600 V |
80 C |
Polyurethane |
SEE SPEC |
SEE SPEC |
36 AWG MIN |
external interconnection of electronic equipment |
| 20236 |
30 V |
80 C |
Polyurethane |
SEE SPEC |
SEE SPEC |
36 AWG MIN |
internal wiring or external interconnection of electronic equipment |
| 20276 |
30 V |
80 C |
N/S |
SEE SPEC |
SEE SPEC |
40 AWG MIN |
CONSTRUCTION A: internal wiring or external interconnection of electronic equipment in class 2 circuits only CONSTRUCTION B: internal wiring of electronic equipment in class 2 circuits only |